Chinese corrosion-resistant magnetic transmission equipment production base China's first production of continuous idling magnetic pump manufacturers
current location:Home>> Products >> Stainless Steel Pumps  Product Details
Untitled Document

MEANING TYCD50-32
T Code of enterprise
Y Submerged pump
C Magnetic driven
50 The inlet dia is 50mm
32 Head is 32m

一、Product Introduction:


FEATURES:

1.TYCD no leakage double shell magnetic submerged pump is designed and manufactured according to HG/T2730-2012 and API685-2000.
2.The flowing-passed components like pump body, inner rotor, pump cover, impeller, distance sleeve, etc, are all made of superior stainless steel or special materials.
3.The flowing-passed components like pump body, inner rotor, pump cover, etc, are all precisly casted of ludox, no impurities, no air holes, no sand holes. Accurate size and smooth runner ensure anti-corrosion and pressure resistance of pump.
4.Impeller is designed and precision casted per CFD computer fluid mechanics and module design, with features of wide and smooth runner, high efficiency, good NPSH performance, small axial force, accurate size and good interchangeability.
6.Rotating ring, shaft sleeve, sleeve bearings are made of SSIC and tungsten carbide material with good characteristic of superior wear resistance, high strength and good anti-corrosion, which guarantee the pump’s working life.
7.New type permanent magnet with good magnetism, high temperature resistant and No demagnetization is selected.
8.The unique automatic axial force balance system, which makes the axial force is almost zero, produce only very minor mechanical friction during long-term running and operation
9.Double sliding bearings structure makes pump run more stable, makes medium flow more smoothly.
10.Enclosed static seal completely solves the problem of dielectric leakage.
Application:
Widely applied to many fields or processes like petroleum, chemical, acid, alkali, rare earth, smelting, pesticides, dyes, medicine, paper making, electroplate, electrolysis, acid pickling, radio, formed foil, research organizations and national defense, etc. Particularly be applicable to delivery medium of flammable, explosive, volatile, toxic, strong acid and alkali, organic solvents and other expensive liquids, etc.
Performance range:design pressure1.6-5.0Mpa, flow1.8-400m3/h, head15-125m, power1.5-110kw
Applicable temperature:-20~350℃
NOTES:Please indicate during ordering if the proportion of medium is larger than 1.3mg/cm3. No idling running. No delivering medium with particles or crystalline.

二、Structure drawing:

 

Part Material Part Material Part Material
146.bracket Ht200 529.1.gasket PTFE 157.impeller 304/316
840.coupling HT200/45# 211.bearing seat 45# 591.impeller nut 304/316
360.bearing gland HT200 161.below bracket 304/316 702.pump body 304/316
921.round nut 45 4002.2.outer magnet assembly permenant flange/ZG 714.filter 304/316
312.bearing GCR15 314.distance sleeve 304/316 917.outlet flange 304/316
359.bearing seat 45 230.rotor permenant magnet/304/316 outlet 304/316
890.square plate Q235 922.bearing SSIC/hard alloy 160.balance tube assembly 304/316
400.gasket PTFE 102.shaft sleeve SSIC/ hard alloy outlet flange 304/316
153.over flange of main pipe 304/316 234.pump shaft 304/316 case body 304/316
158.mian pipe 304/316 156.pump cover 304/316 minimum flow volume 304/316
213.transmision shaft 2CR13 159.gasket PTFE pressure alarm sysytem 304/316
154.below flange of main pipe 304/316 712.thrust collar SSIC/ hard alloy inner isolation  304/316

三、Performance Curve:

四、Performance data sheet:

Type Speed
r/min
Flow
m3/h
Head
m
Efficiency
NPS
m
Inlet×Outlet
mm
Power
kw
25TYDC-20 2900 1.5 22 28 2.5 25×20 2.2
2 20 34.5 2.5
3.2 18.5 36 3
25TYDC-32 2900 1.5 34.3 24 2.5 25×20 3
2 32 32 2.5
3.2 29.6 33 3
25TYDC-50 2900 1.5 52.5 28 2.5 25×20 5.5
2 50 32 2.5
3.2 48 30 3
25TYDC-80 2900 1.5 82 26 2.5 25×20 11
2 80 30 2.5
3.2 78.5 28 3
32TYDC-20 2900 2 22 40 2.5 32×20 2.2
3.2 20 44 2.5
5.5 18.5 42 3
32TYDC-32 2900 2 34.3 40 2.5 32×20 3
3.2 32 44 2.5
5.5 29.6 42 3
32TYDC-50 2900 2 52.5 32 2.5 32×20 5.5
3.2 50 36 2.5
5.5 48 34 3
32TYDC-80 2900 2 82 26 2.5 32×20 11
3.2 80 30 2.5
5.5 78.5 28 3
40TYDC-20 2900 4.4 22 41 2.5 40×25 2.2
6.3 20 46 2.5
8.3 18.5 43 3
40TYDC-32 2900 4.4 34.3 35 2.5 40×25 3
6.3 32 40 2.5
8.3 29.6 38 3
40TYDC-50 2900 4.4 52.5 26 2.5 40×25 7.5
6.3 50 33 2.5
8.3 48 32 3
40TYDC-80 2900 4.4 82 24 2.5 40×25 11
6.3 80 28 2.5
8.3 78.5 28 3
50TYDC-20 2900 7.5 22 43 2 50×32 3
12.5 20 51 2
15 18.5 49 2.5
50TYDC-32 2900 7.5 34.3 33 2 50×32 4
12.5 32 44.5 2
15 29.6 46 2.5
50TYDC-50 2900 7.5 52.5 28 2 50×32 7.5
12.5 50 37 2
15 48 40.5 2.5
50TYDC-80 2900 7.5 82 23 2 50×32 15
12.5 80 32 2
15 78.5 36.5 2.5
65TYDC-20 2900 15 21.8 37 2 65×50 4
25 20 57 2
30 18.5 60 2.5
65TYDC-32 2900 15 35 44 2 65×50 5.5
25 32 53 2
30 30 57 2.5
65TYDC-50 2900 15 53 41 2 65×40 11
25 50 50 2
30 47 53.5 2.5
65TYDC-80 2900 15 82 34 2 65×40 18.5
25 80 46 2
30 78 50 2.5
65TYDC-125 2900 15 127 28 2.5 65×40 30
25 125 39 2.5
30 123 48.5 3
80TYDC-20 2900 30 22.5 53 3 80×65 7.5
50 20 57 3
60 18 47 3.5
80TYDC-32 2900 30 36 52 2.5 80×65 11
50 32 62 2.5
60 29 60 3
80TYDC-50 2900 30 53 53 2.5 80×50 15
50 50 60 2.5
60 47 58 3
80TYDC-80 2900 30 84 44 2.5 80×50 30
50 80 55 2.5
60 75 57 3
80FY-125 2900 30 128 39 2.5 80×50 45
50 125 48 2.5
60 123 47.5 3
100TYDC-20 2900 60 24 59 4 100×80 11
100 20 67 4.5
120 16.5 57 5
100TYDC-32 2900 60 36 56 3.5 100×80 15
100 32 67 4
120 28 68 5
100TYDC-50 2900 60 54 57 3 100×65 30
100 50 67 3.6
120 47 66 4.8
100TYDC-80 2900 60 87 52 3.5 100×65 45
100 80 63 3.8
120 74.5 62 4.8
100TYDC-125 2900 60 133 48 3 100×65 75
100 125 57 3.6
120 118 59 4.2
125TYDC-20 2900 120 23 63 4.5 125×100 22
200 20 72 4.5
240 18 65 5
125TYDC-32 2900 120 35 57 3.8 125×100 30
200 32 70 4.2
240 28 69 5
125TYDC-50 1450 120 55 57 2.5 150×125 45
100 50 70 2.5
240 45 67 3
150TYDC-20 1450 120 132.5 56 4 125×100 22
200 20 65 4.5
240 120 58 5
150TYDC-32 1450 120 52 51 2.5 125×100 30
200 32 57 2.5
240 48.5 53 3
150TYDC-50 1450 120 53 56 2.5 150×125 45
200 50 65 2.8
240 46 58 3.5
200TYDC-20 1450 240 21.5 68 3.5 200×150 37
400 20 74 4.3
460 17.5 70 5
200TYDC-32 1450 240 37 62 3 200×150 75
400 32 74 3.5
460 28.5 72 4
200TYDC-50 1450 240 55 62 3 200×150 110
400 50 73 3.8
460 45 70 4.5
250TYDC-20 1450 600 22 75 4.1 250×200 75
800 20 78 5
960 16 77 6
250TYDC-32 1450 600 34 73 4.8 250×200 90
800 32 75 5.5
960 28 75 6.4
250TYDC-50 1450 600 54.5 55 3.5 250×200 160
800 50 68 4.3
960 39 70 5
300TYDC-32 1450 1550 35 58 3.6 300×250 220
1400 32 74 4.5
1300 26 65 5.4
300TYDC-50 1450 1550 55 65 4.1 300×250 315
1400 50 75 5
1300 42.5 73 6

Installation sketch map and tanker working principal:

1.In order to avoid playing "stuffy pumps" and pump in cases with low flow operation, pump should be seted the minimum backflow;
2.In order to reduce the resistance, pump casing with liquid phase of liquid chlorine tank liquid inlet pipe DN100-diameter pipe at least is recommended
3.Between the pump casing and tank vapor and liquid through the valve in the piping layout control should be achieved independently
4.Minimum liquid level(H):HNPSHr(m)+pipeline loss(m)+0.5(m);
5.The proposal is equipped with frequency converter to adjust the pump outlet pressure and flow rate
6.Recommendations are fitted with flow meter to monitor the flow and avoid excessive flow run damage the pump
7.If the impurity in liquid chlorine, recommended inlet pipe set the basket filter (30 or 40 mesh).

Working principal:
With liquid chlorine pump liquid chlorine is fed into the carburetor, carbure to chloride produces high pressure tank chloride vapor pressure, liquid chlorine tank into the tank of liquid chlorine to achieve safety of liquid chlorine tank car.

 

Virtual product: